一、概述1.检定依据JJG233-2008《压电加速度计检定规程》。2.检定仪器及检定项目检定仪器:8305/2626型标准加速度计套组(821561/863957);4801/4812型中频振动校准系统(853485/1020587);2626电荷放大器(1804951);KEITHLEY-2000多功能数字表(0967813)。检定项目:加速度传感器不同安装方式不同频率下的灵敏度幅值和灵敏度频率响应。频率响应按下列
First, an overview 1. Verification based on JJG233-2008 “piezoelectric accelerometer verification procedures.” 2. Calibration equipment and test items Test equipment: 8305/2626 standard accelerometer package (821561/863957); 4801/4812 type IF vibration calibration system (853485/1020587); 2626 charge amplifier (1804951); KEITHLEY-2000 and more Function Digital Table (0967813). Test items: Acceleration sensor installation of different frequencies under different sensitivity amplitude and sensitivity frequency response. The frequency response is as follows