利用轻水堆系统通用的热工水力分析程序RETRAN 02 ,对DPR 3型200MW深水池供热堆的失水事故进行了分析计算。给出了低温常压的水池型反应堆的计算模型、瞬态特性及计算过程。结果表明 ,瞬态参数都在安全准则的规范之内 ,显示出良好的池式堆的安全特性
The water loss accident of DPR 3 200MW deep pool heating reactor was analyzed and calculated by RETRAN 02, a general thermal hydraulics analysis program of light water reactor system. The calculation model, transient characteristics and calculation process of the reactor at low temperature and pressure are presented. The results show that the transient parameters are within the specifications of the safety guidelines and show the safety characteristics of a good pool reactor