基建工地住宿工棚,如需要设火炉,应注意下列事项:①铁炉距可燃物应不小于150厘米,否则,应用不燃材料隔开;砖炉炉门距可燃物亦不应小于150厘米,其余部分则应不小于37厘米。②铁制烟囱距可燃结构应不小于70厘米,距可燃屋檐应不小于20厘米,高出屋面应不小于50厘米,穿过可燃墙壁、窗户时,烟囱周围应用不燃材料隔开,与周围可燃结构的距离应不小于烟囱本身的直
Infrastructure work site shed, if you need to set the stove, should pay attention to the following: ① iron furnace combustible material should be not less than 150 cm, otherwise, the application of non-combustible materials separated; furnace furnace door from combustible material should not be less than 150 cm, the remaining Some should be not less than 37 cm. ② iron chimney from the combustible structure should be not less than 70 cm away from the combustible roof should be not less than 20 cm above the roof should be not less than 50 cm through the combustible walls, windows, chimneys around the use of non-combustible material separated from the surrounding combustible The structure of the distance should not be less than the chimney itself straight