美刊《工业研究》1972年第6期报道了一条利用计算机系统闭环控制气相色谱仪的消息,摘译如下。一台GC/CPU计算机系统能闭环控制气相色谱仪,使得当试样留于柱内时分析每个样品组份的柱温与载气流量的试验条件最佳化。该系统利用如下事实:给定试样中每个组份有一个最佳温度与载气流量,以取得最佳柱效率与选择性。在工作中该系统在洗提每个峰之后校正柱温与流量,使达到符合于仍在柱中的组份的最佳条件。适应每个组份的流量的
American Journal of Industrial Research, No. 6, 1972 reported the use of closed-loop computer control of gas chromatography news, extracted as follows. A GC / CPU computer system is capable of closed loop control of the gas chromatograph so that the experimental conditions for column temperature and carrier gas flow for each sample component are optimized when the sample is left in the column. The system takes advantage of the fact that there is an optimum temperature and carrier gas flow rate for each component in a given sample for optimal column efficiency and selectivity. In operation, the system calibrates column temperature and flow after each peak is eluted so that the optimal conditions are met for the components still in the column. Adapt to the flow of each component