一、前言宝鸡发电厂3、4号汽轮机系捷制VK50型机组。同型机组国内尚有九台,分布在辽宁(5台)、唐山(2台)、谏壁(2台)电厂。该型机组自投运以来,末五级动叶片均发生不同程度的断裂事故,成为国内频发性叶片断裂事故的典型机组之一。 1971年以来,我们与宝鸡发电厂协作先后对该机组第14、15/18、16/19级动叶片的损坏原因进行分析和改进,取得了显著的效果。为了总结经验,便于推广和应用,在原
First, the preface Baoji Power Plant 3,4 steam turbine Czech-made VK50-type unit. The same type of unit there are still nine units, located in Liaoning (5 units), Tangshan (2 units), Jianbi (2 units) power plant. Since the unit was put into operation, the last five stages of moving blades have occurred different degrees of fracture accidents, becoming one of the typical units of the domestic frequent blade failure. Since 1971, in collaboration with Baoji Power Plant, we have analyzed and improved the causes of damage to the moving blades of No. 14, No. 15, No. 18, No. 18 and No. 19/19, and achieved remarkable results. In order to sum up experience, easy to promote and apply, in the original