2)8 MHz 时钟振荡电路存在故障,一般也会引起不开机的现象。确定8 MHz 时钟振荡电路是否存在故障,可以测量系统控制电路 CPU(31)、(32)脚1.4 V、2.2 V电压是否分别正常?如果正常,可以分别代换 C712、C713、Z701试试;如果仍然不开机,说明(31)、(32)脚外围的振荡电路有故障,也可能是系统控制电路内部的时钟振荡电路存在故障,可以代换一下系统控制电路试试。如果(31)、(32)脚电压较低,说明可能是 C712、C713漏电造成,可以取下 C712、C713进行检查。
2) There is a fault in the 8 MHz clock oscillation circuit, which usually causes a non-power-on phenomenon. Determine if the 8 MHz clock oscillation circuit is faulty and measure the 1.4 V and (32) pins of the system control circuit CPU (31) and (32), respectively. Is the voltage respectively normal? If so, try C712, C713 and Z701 respectively; Still does not boot, indicating (31), (32) peripheral oscillation circuit is faulty, it may be the system control circuit internal clock oscillation circuit failure, you can replace the system control circuit try. If (31), (32) voltage is low, it may be caused by C712, C713 leakage, you can remove the C712, C713 to check.