论文部分内容阅读
埋藏式除颤器的手术期实验是必要的,但必须对患者安全和用于预测性能的足够充分的信息做比较。虽然从每一个患者身上确定阈值特性的方法是不规范的,但是从与某个患者有限的手术期信息相结合而进行的临床试验中集中数据,采用可测量的概率方法,则能用来描述患者的除颤响应。在本文中,将除颤过程模拟为随机事件,其能量(等效于平方根变换了的电压)决定着输出处的除颤概率,其它所有因素作为随机变化量处理。个体概率曲线
Surgical trials of tibial defibrillators are necessary, but comparisons between patient safety and sufficient information to predict performance should be made. Although the method of determining threshold characteristics from each patient is not standardized, data from clinical trials performed in conjunction with limited information on the duration of surgery in a patient, using measurable probabilistic methods, can be used to describe Patient’s defibrillation response. In this article, the defibrillation process is modeled as a random event, the energy of which (equivalent to the square root transformed voltage) determines the defibrillation probability at the output, and all other factors are treated as random variations. Individual probability curve