论文部分内容阅读
一、概述1.测量依据JJG443-2015《燃油加油机检定规程》。2.测量标准100L二等标准金属量器,U=0.025%,k=3;温度计等。3.测量方法在规定的测量环境条件下,用100L二等标准金属量器和辅助设备,以最大流量QL流量点对加油机进行示值测量,测量介质为0#柴油,将标准金属量器中的介质经温度补偿后的体积VBt同加油机示值VJ比较之差值,则为加油机示值误差。二、测量模型及灵敏系数
I. Overview 1. Measurement based on JJG443-2015 “fuel tanker test procedures.” 2. Measuring standard 100L second-class standard metal measuring device, U = 0.025%, k = 3; thermometer and so on. 3. Measurement methods Under the conditions of the specified measurement environment, with 100L second-class standard metal measuring devices and auxiliary equipment to the maximum flow QL flow point on the dispenser for indication measurement, the measuring medium is 0 # diesel, the standard metal measuring device In the media after the temperature compensated by the volume VBt VJ compared with the tanker indication of the difference, then the tanker indication error. Second, the measurement model and sensitivity coefficient