目前国内测定微量锡的方法,为消除大量铁的干扰,通常采用萃取分离比色法测定,操作复杂、灵敏度较低。为此进行了铁锰矿中微量锡的光谱测定方法试验。本法测定锡的范围为0.005—0.3%,满足了科研生产的需要。本法选择了光谱分析缓冲剂、电极形状和分析线对,研究了组份的影响。我们试验了5种缓冲剂:碳粉:碳酸钙:碳酸钠=1:1:1和70:23:7;碳粉:碳酸钙=1:1;碳粉:碳酸钠=1:1;碳粉:碳酸钙:次亚磷酸钠=35:30:35。所试缓冲剂中均加入0.4%三氧化二锑。以锑作内标元素。缓冲剂与试样之比均为1:8。试验
At present, the method of measuring trace tin in China is usually operated by extraction and separation colorimetric method to eliminate the interference of a large amount of iron. The operation is complicated and the sensitivity is low. For this purpose, a method of spectrophotometric determination of tin in ferromanganese ore was carried out. Tin determination of the scope of this method is 0.005-0.3%, to meet the needs of scientific research and production. This method selects the spectral analysis buffer, the shape of the electrode and the analytical line pair to investigate the effect of the component. We tested five buffers: Toner: Calcium Carbonate: Sodium Carbonate = 1: 1: 1 and 70: 23: 7; Toner: Calcium Carbonate = 1: 1; Toner: Sodium Carbonate = 1: 1; Powder: calcium carbonate: sodium hypophosphite = 35: 30: 35. The buffer was added 0.4% antimony trioxide. Antimony as an internal standard element. Buffer and sample ratio of 1: 8. test