我矿务局1—100/8型(6KV同步电动机,功率500KW)和1—40/8型(6KV同步电动机,功率250KW)空压机,所配高压开关柜为电动操作。合闸线圈和脱扣线圈均为直流220伏,可采用直流牵引网路275伏作电源。由于事故或检修,高压6KV线路停电后,直流分闸线圈不能脱扣(需要人工按动停车按钮);复电后,同步电动机自行启动,而励磁又未投入,致使同步电动机失励运转,对电动机威胁很大。因此,将高压开关柜增加无压脱扣装置是很有必要的。我们利用了电容贮能原理,将电容与脱扣线圈并联,待失压后,电容对脱扣线圈放电,分断高压油开关。接线如图所示:
I mine 1-100 / 8 type (6KV synchronous motor, power 500KW) and 1-40 / 8 (6KV synchronous motor, power 250KW) air compressor, equipped with high voltage switchgear for electric operation. Closing coil and trip coil are DC 220V, DC traction network can be used as a 275 V power supply. Due to accident or overhaul, the high-voltage 6KV line after power failure, the DC sub-gate coil can not be tripped (need to manually press the stop button); after the re-start, synchronous motor self-starting, and excitation has not put into operation, resulting in synchronous motor failure operation, Motor threat is great. Therefore, it is necessary to increase the pressure switchgear without pressure trip device. We use the principle of capacitor energy storage, the capacitor in parallel with the trip coil to be loss of pressure, the capacitor discharge coil tripping, breaking the high-pressure oil switch. Wiring as shown: