论文部分内容阅读
1983年1月15~16日,在汕头市召开了汕头超声仪器研究所试制CTS-25型非金属超声波检测仪鉴定会。参加鉴定的有来自全国54个单位87名代表。该仪器经中国建研院结构所和陕西省建研所现场试用,使用效果良好。会上又经测试小组测定,仪器已达到设计的有关技术指标。会议认为:“CTS-25型非金属超声波检测仪性能良好,工作稳定可靠,是目前国内同类产品中水平先进、功能较全的仪器。与国外同类仪器相比,其穿透距离、接收系统灵敏度、稳定性、测时方法等主要技术指标均达到或优于七十年代英国《PUNDIT》仪器的水平”。与会代表一致认为,该仪器设计是合理的,试制是成功的,一致同意通过鉴定,可以投入生产。
On January 15th to 16th, 1983, the Shantou Ultrasonic Instrument Research Institute held a trial production of the CTS-25 non-metallic ultrasonic tester. There were 87 representatives from 54 units across the country. The instrument was tried on the spot by the China Institute of Industrial Science and Technology and the Shaanxi Institute of Construction, and the results were good. At the meeting, it was determined by the test team that the instrument has reached the relevant technical specifications of the design. The conference considered that: "The CTS-25 non-metallic ultrasonic detector has good performance and stable and reliable operation. It is an advanced level, full-featured instrument in similar products in China. Compared with similar foreign instruments, it has a penetration distance and a receiving system. The major technical indicators such as sensitivity, stability, and timing methods all met or exceeded the level of British PUNDIT instruments in the 1970s. The delegates agreed that the design of the instrument was reasonable, the trial production was successful, and they all agreed that they could be put into production.