高炉热风阀时常损坏,需要休风更换,我厂以往更换一次热风阀高炉休风达36小时,大大影响了正常生产,在十大快速检修经验中曾缩短到6小时,在1959年又缩短至21分钟,1964年又打破了21分钟又创15分钟快速更换热风阀的新纪录。其主要经验是; (一)提高检修质量,换前准备好备品,实行组立更换。热风阀的水圈往往烧坏,经检查其原团是压石棉绳的环钢掉下或者松动,造成热风由水圈和阀亮间隙流出,因此水圈被烧坏。此外水圈进出水管根部往往漏水,或中间隔板漏水,促成了水压低;流水短路降低了冷却效果使水
Blast furnace hot air valve is often damaged, the need to rest off, I changed the factory hot blast valve blast off 36 hours, greatly affected the normal production, in the top ten quick maintenance experience has been shortened to 6 hours in 1959 and shortened to 21 minutes in 1964, breaking the 21 minutes and breaking another 15 minutes to quickly replace the hot air valve new record. The main experience is; (A) to improve the quality of overhaul, ready for the replacement of spare parts, the establishment of replacement. Hot water valve ring is often burned, after checking its original group is asbestos rope ring fell or loose, resulting in hot air from the water ring and valve bright gap outflow, so the water ring is burned. In addition, the water ring often leaks in and out of the water pipe root, or water leaks in the middle partition, resulting in a low water pressure; short-circuiting of the water reduces the cooling effect so that the water