论文部分内容阅读
在1500℃,感应炉熔炼的铸铁中吹入氧气和二氧化碳气,在铁液中氮含量为0.017%的条件下,能有效脱氮,分别在5min和20min内使氮含量下降到0.004%.
At 1500 ℃, oxygen and carbon dioxide gas were blown into the cast iron melted by the induction furnace. The nitrogen content in the molten iron was 0.017%, which could effectively denitrify the nitrogen content to 0 in 5min and 20min, respectively. 004%.