荆门炼油厂润滑油加氢精制装置的三台换热器分别于1974年和1975年到货。由于设备库存时间长,加之管理不善,接管法兰梯形槽密封面锈蚀严重,致使试压工作无法进行。经研究将三台换热器的六个接管法兰割下,进行密封面的机械加工,然后进行现场焊接。鉴于目前国内20CrMo9现场施焊经验不多,下面将施焊的主要情况作一简单介绍,以供参考。换热器的主要有关技术参数:设计温度:管程420℃,壳程370℃;设计压力:管程100kg/cm~2,壳程100kg
Jingmen refinery lubricants, hydrotreating units of the three heat exchangers were in 1974 and 1975 arrival. As equipment inventory for a long time, combined with poor management, take over the flange trapezoidal groove sealing surface serious corrosion, resulting in pressure test can not be carried out. After the study of three heat exchanger six takeover flange cut off, the sealing surface machining, and then on-site welding. In view of the current domestic 20CrMo9 welding experience in the field less, the following will be the main situation of welding for a brief introduction for reference. The main technical parameters of the heat exchanger: Design temperature: 420 ℃ pipe, shell 370 ℃; design pressure: pipe 100kg / cm ~ 2, shell 100kg