RJJ—75型井式气体渗碳电炉,是两区供电。上区功率是24瓩,下区功率是51瓩,空载损失是20瓩,所以电炉在恒温期间,不论上区或下区一旦失控,继续供电,都能造成超温。试验证明:在任一温度下恒温时,上区供电、下区断电,经过10分钟,上区温度可增高60℃以上,下区温度只降低1℃。在下区供电、上区断电时,经过10分钟,下区温度可增高75℃以上,上区温度增高3—5℃,以上试验证明:不仅能超温,并且炉温不均匀,这样工件容易造成废品,炉子使用寿命也受到极大影响,严重时需要重新更换电阻丝。
RJJ-75-type gas-carburizing gas furnace, is the two districts power supply. The power in the upper zone is 24 瓩, the power in the lower zone is 51 瓩 and the no-load loss is 20 瓩. Therefore, when the electric furnace is out of control or continues to supply power during the constant temperature period, the over-temperature can be caused. Test proved: constant temperature at any temperature, the district power supply, the next district power, after 10 minutes, the upper zone temperature can be increased above 60 ℃, lower zone temperature decreased by only 1 ℃. In the next district power supply, the district power, after 10 minutes, the lower zone temperature can be increased above 75 ℃, the upper zone temperature increased 3-5 ℃, the above test shows that: not only over-temperature, and uneven temperature, so that the workpiece is easy Resulting in waste, stove life is also greatly affected, in severe cases need to replace the resistance wire.