论文部分内容阅读
用反相高效液相色谱法,测定了两种制剂中的双氯灭痛含量。色谱条件为:SphersorbC185μm(4×250mm)色谱柱;流动相为0.25mol/L醋酸钠缓冲液(pH3.6)-甲醇(36:64);紫外检测波长282nm。双氯灭痛在2~10mg/L浓度范围内呈良好线性关系(r=0.9993)。两种制剂的回收率为:双氯灭痛肠溶衣片99.9%,RSD2.03%;感冒通片98.7%,RSD1.61%。最低检测浓度为10μg/L。内标为醋酸地塞米松。
The contents of diclofenac in both preparations were determined by RP-HPLC. Chromatographic conditions: SphersorbC185μm (4 × 250mm) column; mobile phase 0.25mol / L sodium acetate buffer (pH3.6) - methanol (36:64); UV detection wavelength of 282nm. Diclofenac in the 2 ~ 10mg / L concentration range showed a good linear relationship (r = 0.9993). The recoveries of the two preparations were as follows: diclofenac enteric-coated tablets 99.9%, RSD 2.03%; cold pass 98.7%, RSD 1.61%. The lowest detection concentration of 10μg / L. Internal standard dexamethasone acetate.