为评价间日疟原虫 PCR检测试剂盒在疟疾现场监测中的效果 ,采用该试剂盒和常规镜检法对安徽省疟疾流行区的 940份血样进行了检测 ,结果显示 ,该 PCR检测试剂盒对 2 34例在校中学生的人群带虫调查的阳性检出例数 (5例 )高于常规镜检 (2例 ) ,所需检测时间和费用均低于常规镜检。同时 ,采用两法对 5 19例门诊发热病人血片 (镜检初检阳性 16例 ,阴性 5 0 3例 )进行复核 ,镜检复核发现漏诊 2例 ,PCR复核发现漏诊 6例 ,所需复核时间和费用也均低于常规镜检。采用两法对 187例门诊“三热”病人进行被动病例检测 ,PCR检出阳性例数略高于镜检 ,但单位检测时间和费用也高于镜检。现场评价结果提示 ,该 PCR检测试剂盒可替代镜检用于疟疾监测中大样本检测 ,且具有敏感、特异、高效和价廉的特点。
To evaluate the efficacy of the PCR kit for malaria in the on-site surveillance of malaria, 940 blood samples from malaria-endemic areas in Anhui Province were tested using the kit and conventional microscopy. The results showed that the PCR kit The number of positive cases (5 cases) of 34 cases of secondary school students surveyed with worms was higher than that of the routine examination (2 cases), and the time and cost required for the tests were lower than that of the routine examination. At the same time, two methods were used to check the blood film of 5 19 outpatients with fever (positive 16 cases and negative 503 cases), 2 cases were missed by microscopic examination, 6 cases were missed by PCR test, Time and cost are also lower than the conventional microscopy. Two methods were used to detect passive cases in 187 outpatients with “three fever”. The number of positive cases detected by PCR was slightly higher than that of microscopic examination, but the unit testing time and cost were also higher than those of microscopic examination. The field evaluation results suggest that the PCR detection kit can be used instead of microscopy for large sample detection in malaria surveillance and is sensitive, specific, efficient and inexpensive.