用电阻网络模拟方法计算了元件的温度分布,确定了热点的位置和最高壁面温度值。 元件简图示于图1。计算所用参数见表1。为保证内外流道的宽度,元件上下端置有星形定位架,它有三个爪子,爪子宽3毫米,高10毫米。由于元件内壁被爪子遮盖的区域传热恶化,计算时将此处当作绝热的。元件的上下端面也按绝热考虑。
The temperature distribution of the element was calculated by the resistance network simulation method, and the location of the hot spot and the temperature of the highest wall surface were determined. The schematic diagram of the component is shown in FIG. 1. The parameters used in the calculation are shown in Table 1. In order to ensure the width of the inside and outside the flow path, the device is placed on the lower end of the star positioning bracket, which has three claws, claws 3 mm wide and 10 mm high. Due to the deterioration of heat transfer in the area covered by the pawls on the inner wall of the element, this is treated as thermal insulation. The top and bottom of the components are also considered adiabatic.