论文部分内容阅读
针对本钢6号高炉投产后,喷煤管路在喷吹过程中暴露出的问题,通过调研对6号炉喷煤管路路由的走向和现场实际情况以及使用状况的分析和观察,找到问题的原因,提出改进措施并进行实施。
According to the problems exposed during the injection of coal injection pipe after the Bengang No.6 blast furnace was put into operation, the problems were found through the analysis of the route of the No.6 furnace coal injection pipe and the analysis and observation of the actual conditions and the actual conditions on the site. The reason, put forward the improvement measure and carry it out.