一、概述1.测量依据JJG150-2005《金属布氏硬度计》检定规程。2.环境条件温度:18℃~28℃,相对湿度:不大于70%。3.标准器具标准布氏硬度块(以下简称“标准块”)。二、校准过程1.用相应规格的标准块分别对硬度计示值进行校准。2.在标准块上均匀分布地测定5点。3.所测5点硬度的平均值与标准块标称值之差为硬度计的示值绝对误差。
I. Overview 1. Measurement based on JJG150-2005 “metal Brinell hardness” test procedures. 2. Environmental conditions Temperature: 18 ℃ ~ 28 ℃, relative humidity: not more than 70%. 3. Standard equipment standard Brinell hardness block (hereinafter referred to as “standard block ”). Second, the calibration process 1. With the corresponding standard blocks were calibrated hardness tester indication. 2. 5 points evenly distributed on the standard block. 3. The difference between the average of the measured 5 point hardness and the nominal value of the standard block is the indication absolute error of the hardness tester.