JS-3型钢丝拉力试验机是试验钢丝强度和伸长率的专用仪器。现将钢丝拉力试验机常见的故障的分析及排除方法列出,仅供参考。 故障现象之一:仪器调整状态下跳字,四位数一齐跳动。 产生原因之一:一般是印刷板YB2集成块7135的基准电压1伏不准引起。 排除方法:1、
JS-3 wire tensile testing machine is a test wire strength and elongation of special equipment. Wire tensile testing machine now common fault analysis and troubleshooting are listed, for reference only. One of the symptoms of failure: jump under the state of instrument adjustment, four-digit beating together. One of the reasons: Generally printed board YB2 7135 reference voltage of 1V is not allowed to cause. Remedy: 1,