矿井高压电网的安全运行,虽有诸多方面的因素,但其中以单相接地的保护及措施最为重要.对于6kV供电网络大的矿井,由于出线回路多,单相接地的机率也多,当供电网络的电容电流超过20安时,因单相接地故障造成设备损坏及事故的机率也多.因此,对单相接地电容电流加以限制,是保证矿井6kV电网安全运行必不可少的条件.限制单相接地电容电流措施之一:采用消弧线圈进行补偿.霍县矿务局白龙矿井采用交流电机驱动,无级调节电感的消弧线圈,用以补偿电容电流,可实现手动和电动闭锁操作、电动远方和就地操作,参见图1.该设备由罗马尼亚引进,与我国生产的消弧线圈相比,其主要区别在于具有可移动的铁芯,通过电感的调节来改变补偿电流的大小,以使消弧线圈工作在最佳状态.由于6kV网络的供电状况是变化的,其电容电流的大小也是相应变化的,如果能有电容电流的检测装置,那么此种消弧线圈便可实现跟踪等补偿.
The safe operation of high-voltage mine network, though there are many factors, but the protection and measures of which single-phase ground is most important for large 6kV power supply network mine, due to more outlet circuit, the probability of single-phase grounding, when the power supply When the capacitance of the network is more than 20 A, it is more likely that the equipment will be damaged and the accident will occur due to the single-phase grounding fault.Therefore, the limitation of the single-phase grounding capacitor current is an indispensable condition to ensure the safe operation of the mine 6kV power grid. Phase grounding capacitor current measures: the use of arc suppression coil compensation.Huoxian Mining Bureau Bailong mine using AC motor drive, infinitely adjustable inductor arc suppression coil, to compensate for the capacitive current, enabling manual and electric locking operation , Electric remote and on-site operation, see Figure 1. The device imported from Romania, compared with the production of arc suppression coil in China, the main difference is that with a removable core, the inductance adjustment to change the size of the compensation current, So that the arc suppression coil work in the best condition.As 6kV network power supply conditions change, the size of the capacitor current is also a corresponding change, if there is a capacitive current Detection device, then such arc suppression coil tracking compensation can be achieved.