目的:改进水中铝的测定方法。方法:用乙酸—乙酸钠缓冲体系代替乙二胺缓冲体系,用标准样品验证方法的可靠性,对采用聚合氯化铝作混凝剂的水样进行加酸加热加碱的预处理后,再用乙酸—乙酸钠缓冲体系测定。结果:采用乙酸—乙酸钠缓冲体系测定标准样品,结果在标准样品给定值范围内,经过预处理后的水样其测定结果明显高于未处理就测定的结果。结论:采用乙酸—乙酸钠缓冲体系测定铝,结果准确可靠,试剂配制简便易行而且安全,采用聚合氯化铝作混凝剂时,将水样进行加酸加热加碱的预处理才能准确测定水中铝的含量。
Objective: To improve the determination of aluminum in water. Methods: The acetic acid - sodium acetate buffer system instead of ethylenediamine buffer system, with a standard sample to verify the reliability of the method, the use of polyaluminum chloride as a coagulant water samples with acid heating and alkali pretreatment, and then Acetate - sodium acetate buffer system. Results: The acetic acid - sodium acetate buffer system for the determination of standard samples, the results within the range of the standard sample, after pretreatment of the water samples were significantly higher than the measured results of untreated. Conclusion: Acetic acid - sodium acetate buffer system for the determination of aluminum, the results are accurate and reliable reagent preparation is simple and safe and safe, the use of polyaluminum chloride as a coagulant, the water sample with acid heating and alkali pretreatment can accurately determine Aluminum content in water.