七煤(集团)公司新兴矿生进入二水平,矿井通风能力不足,为此把矿井通风系统由分区抽出式改造为中央边界与分区混合式,安装了2台 BDK-10-No36型轴流式主扇和2台 YBF-710-10型560×2kw 电机。改造前为6个回风井12台4-72-11No 2OB 离心式主扇和12台 JS-148—8型240kw 电机,矿井总风量为 Q=233m3/S,负压平均为200mmH20。改造后取消了10台离心式主扇,保留了一个回风井,该井改造前通风工况点为 Q=40m3/S,H=240mmH20。为了全面了解2台新主扇性能,2000年10月13日、14日、17日,公司通风处、机电处、矿通风机电部门及厂家联合对2台主扇进行了30°、35°、37°、40°四种叶片安装角度下的性能测定。一、测定技术布置1、测点布置:如图1所示,Ⅰ-Ⅰ断面为主测压断面,Ⅱ-Ⅱ断面为辅助测压断面。Ⅲ-Ⅲ为辅助测风断面,用风表测主扇的出口风量。
As the emerging coal miners of No. 7 Coal (Group) Company entered the second level and the ventilation capacity of the mine was not enough, the ventilation system of the mine was transformed from the district extraction type into a hybrid with the central boundary and the district. Two BDK-10-No36 axial flow type Main fan and two YBF-710-10 560 × 2kw motor. Before the retrofitting, there were 12 4-72-11No 2OB centrifugal main fans and 12 JS-148-8 240kW motors for 6 return air shafts. The total air volume of the mine was Q = 233m3 / S and the average negative pressure was 200mmH20. After the transformation, 10 sets of centrifugal main fans were canceled and one air return well was reserved. Before the modification, the ventilation points were Q = 40m3 / S and H = 240mmH20. In order to fully understand the performance of the two new main fans, Ventilation Department, Mechanical and Electrical Department, Mine Ventilation and Electrical Department and the manufacturers jointly conducted 2 sets of main fans at 30 °, 35 °, 37 ° on October 13, 14 and 17, 2000 °, 40 ° four kinds of blade installation angle performance measurement. First, the determination of technical arrangements 1, measuring point layout: As shown in Figure 1, Ⅰ-Ⅰ cross-section of the main measured pressure section, Ⅱ-Ⅱ cross-section of the secondary section to help pressure. Ⅲ-Ⅲ to assist the wind measurement section, with a wind meter to measure the main fan outlet air volume.