论文部分内容阅读
目的研究巡测仪的时间修正系数。方法利用电路原理和公式并结合实验推算出巡测仪时间修正系数。结果时间修正系数公式为F(t)=1/(1-e~(-λ×t))。结论使用巡测仪进行放射防护检测时应该对数据进行修正。
Objective To study the time correction coefficient of the touring instrument. Methods Using the circuit principle and formula and combined with the experiment, the time correction coefficient of the surveying instrument is deduced. The result of the time correction coefficient formula F (t) = 1 / (1-e ~ (-λ × t)). Conclusion The data should be corrected when using radiometer testing with a tourimeter.