【摘 要】
:
Radiochromic film is a useful tool for beam quality assurance, but accurate response assessment of the film is still a problem. In this study, the response unce
【机 构】
:
Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Na
论文部分内容阅读
Radiochromic film is a useful tool for beam quality assurance, but accurate response assessment of the film is still a problem. In this study, the response uncer-tainties of HDV2 film were investigated using a fiatbed scanner from both the scanning settings and interscan variability. Scanning settings are fixed conditions for scanning, including scanning resolution and focus setting. In this study, multipeak distributions of pixel values were found under some dots-per-inch values, which should be avoided, and the optimal setting of 2000 dpi without this problem was selected. By changing the focus setting, the relative standard deviation of pixel values was reduced by 36–50%. The infiuence of the interscan variability induced by three factors was investigated, including the outside illumination intensity, film homogeneity, and operating temperature. Scanning the film before and after irradiation at the same position was recommended. Moreover, the suitable operating temperature range for the scanner was found to be 15–24°C, which results in stable film responses. Regarding the studied factors, correction meth-ods and strategies were proposed, and the accurate response assessment of HDV2 film was realized. Finally, a standard operating procedure for response assessment of films was introduced. It can help other researchers study more scanners, films, and particle types.
其他文献
目的了解济宁市任城区食品和公共场所从业人员HBsAg携带情况,为科学防控提供依据。方法采用酶联免疫法对2007年5858名食品及公共场所从业人员进行HBsAg检测,并进行统计学分析
The dynamic evolution of the charm hadron in hot quark matter was studied in the framework of a mul-tiphase transport (AMPT) model. We first reproduced the open
目的结合医疗行业物联网系统的建设现状,设计一种基于SaaS模式的医疗物联网信息服务平台。方法本系统采用数据融合的方式将现有医疗物联网系统进行信息整合,设计了一套标准的
Because of the growing conce over the radia-tion dose delivered to patients, X-ray cone-beam CT (CBCT) imaging of low dose is of great interest. It is dif-ficul
A helium cryogenic system is designed by the Institute of Mode Physics, Chinese Academy of Sci-ences, to supply different cooling powers to the cryomod-ules of
党中央、国务院作出的建设创新型国家的决策,是事关社会主义现代化建设全局的重大战略决策.建设创新型国家,核心就是把增强自主创新能力作为发展科学技术的战略基点,走出中国
NG-CT-10 and NG-CT-20 are newly developed grades of nuclear-grade graphite from China. In this study, their oxidation behaviors were experimentally investigated
The transverse emittance of the extracted beam from the heavy ion medical machine cyclotron is measured and then optimized for injection into the synchrotron. F
A real-time double-ring neutron time-of-flight (TOFII) spectrometer system has been proposed to achieve plasma diagnosis on HL-2M tokamak with a relatively high
The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences o