1986年3月,我厂热轧机的主电机运行不正常,在负载电流超过1万安培时,主电机电刷会产生电火花,并有可能将主电机烧毁。为了保证设备安全和生产的顺利进行,必须将电流限制在1万安培以下,进行限流生产。为此,在总厂和分厂有关领导的安排和指导下,成立了热轧工艺规程测算小组。对热轧工艺规程进行重新校核,使每道次的负载电流不超过1万安培,并且负载分配比较平衡。工作的重点放在LY12、LF6合金上1500、2480毫米的大宽板的校核上。我们应用微机在热轧工艺规程校核中的作法如下:
In March 1986, the main motor of our hot-rolling mill operated abnormally. When the load current exceeded 10,000 amperes, the main motor brush would generate electric spark and possibly destroy the main motor. In order to ensure the safety of equipment and the smooth progress of production, the current must be limited to less than 10,000 amperes for current limiting production. To this end, in the general plant and branch leaders and arrangements under the guidance of the establishment of a hot-rolled process planning team. Hot-rolled process re-check the program, so that each load current does not exceed 1 million amperes, and the load distribution is more balanced. The focus of work on the LY12, LF6 alloy 1500,2480 mm wide on the check. We use the computer in the hot-rolled process in the process of verification practices are as follows: