The clinical value of enzyme-multiplied immunoassay technique monitoring the plasma concentrations o

来源 :Journal of Pharmaceutical Analysis | 被引量 : 0次 | 上传用户:ysminnpu
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
The feasibility and the clinical value of the enzyme-multiplied immunoassay technique(EMIT)monitoring of blood concentrations of cyclosporine A(CsA)in patients treated with CsA were investigated after kidney transplantation.The validation method was performed to the EMIT determination of CsA blood concentration,the CsA whole blood trough concentrations(C0)of patients in different time periods after renal transplantation were monitored,and combined with the clinical complications,the statistical results were analyzed and compared.EMIT was precise,accurate and stable,also with a high quality control.The mean postoperative blood concentration of CsA was as follows:<1 month,(281.4±57.9)ng/mL;2-3 months,(264.5±41.2)ng/mL;4-5 months,(236.4±38.9)ng/mL;6-12 months,(206.5±32.6)ng/mL;>12 months,(185.6±28.1)ng/mL.The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14.1%,significantly lower than that of the none-recommended dose group(37.2%)(P<0.05);the transplantation rejection rate was 4.4%,significantly lower than that of the none-recommended dose group(22.5%)(P<0.05).Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible,and is able to reduce the CsA toxicity and rejection significantly,leading to achieving the desired therapeutic effect. The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT) monitoring of blood concentrations of cyclosporine A (CsA) in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration , the CsA whole blood trough concentrations (CO) of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality (281.4 ± 57.9) ng / mL; 2-3 months, (264.5 ± 41.2) ng / mL; 4-5 months, (236.4 ± 38.9) ng / mL; 6-12 months, (206.5 ± 32.6) ng / mL;> 12 months, (185.6 ± 28.1) ng / mL.The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14.1% than that of the none-recommended dose group (37.2%) (P <0.05); the transplantation rejection rate was was 4.4%, significantly lower than that of the none-recommended dose group (22.5%) (P <0.05) .Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieve the desired therapeutic effect.
其他文献
2017年4月1日,国家卫生计生委和国家中医药管理局联合发布的《电子病历应用管理规范(试行)》正式施行。由此,病历的归属、保护、利用等相关法律问题再次受到广泛关注。病历应
安全生产工作是一项很重要的工作,也是一门学问,作为一名厅级领导,分管了7年安全工作,在实践中学到了不少东西。我初步总结一下,要做好工作,关键在于经常地研究新情况,解决新
本刊讯1月12 日。劳动部向各地劳 动部门发出 1991年 锅炉压力容器安全监 察工作要点,要求结 合本地情况贯彻执 行。工作要点如下: 一、继续搞好在用锅炉压力容器治理整顿,积
冶金工业部委托冶金部安全环保研究院组织编制的《炭素安全规程》,已经冶金工业部批准,并将于1990年6月1日颁布执行。该规程系冶金系统第一部炭素安全法 Ministry of Metal
ASUS V1尊贵商务系列笔记本是华硕为高级商务人员度身定做的至爱数码伴侣。它典雅的造型、坚固的外壳、强大的双核处理能力、高清显示屏、坚固的指纹锁,无不流露出设计者对于
今年四月甘九日,河南省石油化学工业厅王银忠厅长带队赴“吉化”学习期间,在总结座谈会上作了重要讲话。参加学习的同志一致认为:讲话对学“吉化”活动有指导意义,要求整理印
目的研究老年性耳聋与高血压及高脂血症的相关性。方法采用Madsen M-5型听力计测定了老年男性高血压与高脂血症患者及健康老年人各50例的纯音听阈,各组分为60岁组及70岁组,进行组间比较。结果(1)高血压组、高脂血症组与健康组的平均听阈均随增龄而增高,但两个疾病组中的60岁及70岁组在0.25~8kHz各频率的平均听阈均显著高于同龄健康组(P值<0.05或0.01);(2)听力损伤发生率在高血压
地处绵竹大天池白云山的连二坡煤矿,是天池乡乡办企业。现有职工200人,矿井四口,井口标高1366.5米,开采煤层属二迭纪单一煤层,开采方式为平峒开拓,以掘为主的前进式布置采区
S310的显示屏采用了 MSI独家的 ACV(Amazing CrystalVision)增艳亮彩技术,使屏幕的亮度表现更加出色。同时,除了在键盘上方快捷键的两侧设计了条状的扬声器以外,在机身转轴
只因简单地喜欢孩子,当年填高考志愿时,我毫不犹豫地选择了当一名幼儿园教师。5年的师范教育更让我对教师这份职业满怀期待和崇敬。临近毕业时,我常想,以后的每个清晨都要用微笑迎接每位孩子,每次游戏都要渗透爱的教育,每个孩子的一汤一饭、一衣一帽都必须细心照料,每日都要耐心地与家长交流孩子们的成长故事……  可是真正踏入幼儿园这扇大门后,我惊觉现实与美好的理想之间的距离似乎遥不可及。在孩子们的眼神里我读到我
期刊