论文部分内容阅读
1电子模块失效分析二例1.1对数视放模块DSF-101.11失效模式:小信号输出波形斜顶,波形参数见图1.1。1.12失效环境:整机温度冲击(+125℃~-55℃)1.13模块失效原因:反馈回路输出滤波电容内部电极开路。1.14模块失效诊断1.141高温
1 Failure Analysis of Electronic Module 1.1 1.1 Logarithmic Play Module DSF-101.11 Failure Mode: Small Signal Output Waveform Ramp, Waveform Parameters See Figure 1.1.1.12 Failure Environment: Total Temperature Impact (+125 ℃ ~ -55 ℃) 1.13 module failure causes: feedback circuit output filter capacitor internal electrode open. 1.14 module failure diagnosis 1.141 high temperature