中盐新东化工发展有限公司分别于2004年和2007年上了两台75T/H循环硫化床锅炉,运行至今出现两次结焦事故,经常性爆管事故,一次锅炉进水偏酸性事故,还有两次锅炉内部浇注料脱落以及2号锅炉出力不足,导致我厂循环硫化床锅炉热效率低和不能稳定连续运行。这些问题的存在是因为人员培训不够,燃烧控制不稳定,造成热效率不高,厂用电率和故障率高,经济性,可靠性差,停炉事故频发,本文着重介绍:改进运行控制、完善设备、提高运行人员业务水平,提高循环流化床锅炉热效率的行之有效的具体措施,以供同行参考。
Salt in the new East Chemical Development Co., Ltd. in 2004 and 2007, respectively, on the two 75T / H circulating fluidized bed boiler, the operation has so far two coking accidents, recurrent pipe burst accident, a boiler water acidity accident also There are two boiler internal castable shedding and the second boiler output is not enough, resulting in our factory circulating fluidized bed boiler thermal efficiency and can not be stable continuous operation. These problems exist because of insufficient personnel training, instability of combustion control, resulting in low thermal efficiency, high power consumption and failure rate, low economy and reliability, and frequent occurrence of shutdown. This article focuses on improving operation control and perfection Equipment, improve operational staff operational level, improve the thermal efficiency of circulating fluidized bed boiler effective measures for specific reference.