电位溶出分析是近年发展起来的一种新的电分析化学技术。在电位溶出分析中,痕量金属首先电解富集在汞膜电极中然后通过溶液中氧化剂氧化溶出,并记录溶出过程的电位-时间曲线,这种方法操作简便,灵敏度高,元素之间干扰小。本文介绍了利用微型计算机控制的电位溶出分析系统,讨论了仪器的硬件结构和软件设计,利用微机实现了恒电位,自动存取分析方法和数据,分析过程自动控制,自动扣除电容本底和数据平滑,采用静止拟微分电位溶出方式使其灵敏度大大提高。富集五分钟最低可检测0.08ng/ml镉。在1ng/ml的镉离子和1ng/ml铅离子浓度下,连续测定11次,其相对标准偏差分别为3.8%和4.9%。
Potentiometric dissolution analysis is a new type of electroanalytical chemistry developed in recent years. In the potential dissolution analysis, the trace metals are firstly electrolyzed and enriched in the mercury film electrode and then oxidized and dissolved by the oxidant in the solution, and the potential-time curve of the dissolution process is recorded. This method has the advantages of simple operation, high sensitivity and small interference between elements . In this paper, the microcomputer-controlled potentiometric dissolution analysis system is introduced. The hardware structure and software design of the instrument are discussed. The potentiometer, automatic access analysis method and data are realized by microcomputer. The automatic control of the analysis process, automatic deduction of capacitance background and data Smooth, static quasi-differential potential dissolution method to greatly enhance the sensitivity. Enrichment Minimal detectable 0.08 ng / ml cadmium for five minutes. The relative standard deviations were 3.8% and 4.9%, respectively, for 11 consecutive determinations at 1 ng / ml cadmium and 1 ng / ml lead.