目的了解泉州市生活饮用水卫生状况及其影响因素。方法对2012—2014年泉州市生活饮用水进行监测,以GB 5749-2006《生活饮用水卫生标准》评价分析。结果 2012—2014年共监测生活饮用水1 675份,总合格率64.2%。3年检测合格率分别为63.7%、66.6%和62.5%;分散式供水合格率仅27.7%,集中式供水合格率91.0%;枯水期和丰水期合格率分别为68.5%、60.6%。分散式供水的微生物指标超标严重,菌落总数、总大肠菌群和耐热大肠菌群的不合格率分别为38.9%、45.8%和30.3%;集中式供水中,游离余氯、浑浊度和铁超标较多。结论泉州市生活饮用水总体卫生质量有待提高,水质监管部门应加强监管。
Objective To understand the sanitary status of drinking water in Quanzhou and its influencing factors. Methods 2012-2014 Quanzhou drinking water monitoring, with GB 5749-2006 “drinking water health standards” evaluation analysis. Results A total of 1 675 drinking water were monitored during 2012-2014 with a total pass rate of 64.2%. The passing rate of 3-year inspection was 63.7%, 66.6% and 62.5% respectively. The passing rate of decentralized water supply was only 27.7% and the qualified rate of centralized water supply was 91.0%. The pass rates in dry season and wet season were 68.5% and 60.6% respectively. Microbial indicators of decentralized water supply exceeded the standard seriously, the total number of colonies, total coliform and heat-resistant coliform bacteria were 38.9%, 45.8% and 30.3%, respectively; in centralized water supply, free residual chlorine, turbidity and iron More than excessive. Conclusion The overall sanitary quality of drinking water in Quanzhou need to be improved, and the water quality regulatory authorities should strengthen supervision.