秦山第二核电厂主环路温度计故障分析与处理

来源 :核动力工程 | 被引量 : 0次 | 上传用户:descendant_of_shang
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
针对秦山第二核电厂1、2号机组运行初期发生的主环路温度计的典型故障,通过对温度计进行解剖和材料分析、与其他核电厂对比分析、试验室和现场振动分析,确定主环路温度计的故障原因,提出处理方案。结果表明,温度计失效原因为套管的强度不够大,套管与温度计发生碰撞导致温度计末端损坏和破裂;温度计外壁加环改进方案可有效解决故障问题。 Aiming at the typical failure of the main loop thermometer occurred in the operation of Unit 1 and 2 of Qinshan No.2 nuclear power plant, the main loop was determined through the anatomy and material analysis of the thermometer, comparative analysis with other nuclear power plants, laboratory and on-site vibration analysis Thermometer malfunction causes, put forward the solution. The results show that the cause of the failure of the thermometer is that the strength of the casing is not big enough, and the collision between the casing and the thermometer causes the end of the thermometer to be damaged and ruptured. The improved solution of the external wall of the thermometer can effectively solve the problem of failure.
其他文献
采用主曲线方法的单温度法和多温度法,对国产反应堆压力容器(RPV)材料的预裂纹夏比试样(PCVN试样)和1/2 PCVN试样进行测试分析,获得参考温度(T0).对试验结果采用尺寸限度常数
淬火冷却中球体表面蒸汽膜的厚度是不断减小的。由于介质内部不可避免的扰动,任何部位的蒸汽膜厚度都处在震荡变化之中。图12表示球体试样上蒸汽膜厚度的这两种变化。其中图(
针对RCC-M评定准则对部分部件的热棘轮现象无法做出安全性评定的问题,综合考虑塑性变形和弹性变形的影响,详细分析CPR1000核电厂稳压器电加热喷雾接管的热棘轮现象。计算结果
从基本的质量、动量方程出发,针对多孔介质碎片床,开发基于有限元法的二维稳态堆芯碎片床分析程序,并分析系统压力、颗粒直径、孔隙率等相关参数对于碎片床冷却能力的影响,为
针对核反应堆专设安全设施试验间隔期的优化,以传统的专设安全设施组成设备平均可用度模型为基础,提出采用较少假设近似并考虑设备在备用、试验和检修3阶段状态关联的可用度
以中国改进型压水堆1000 MW核电站(CPR1000)蒸汽发生器(SG)为对象,分析SG上部水平支承垫条产生热膨胀弯曲变形后间隙测量值与实际间隙值不一致的原因,给出垫条结构的改进措施
介绍反应堆冷却剂温度测量通道校准(TP RCP63)试验的内容,分析数字化技术对核电厂TP RCP63试验的影响,着重论述与模拟技术核电厂相比存在的变化与问题,并提出采用数字化技术
运用一种双分布函数多相格子Boltzmann模型,对几种气泡运动进行数值模拟,并分析了模型本身。指出在使用模型进行分析计时应注意的一些问题。进一步对气泡上升过程中流场压力
根据高压安注死管段内的热工水力特性,分析管道热疲劳发生的机理.提出大亚湾核电站和岭澳核电站一期高压安注死管段的改进方案,并对改进方案中的新增管线进行疲劳分析后可得,
采用计算流体力学(CFD)数值模拟与实际实验参数对比分析风冷系统冷却特性,评估风冷系统设计合理性并优化限值。结果表明,控制棒数量的增加,有利于风量分配的均匀化和风冷系统