肾上腺腺瘤宽体探测器CT灌注成像特点

来源 :中国医学影像技术 | 被引量 : 0次 | 上传用户:Tsianyong
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的探讨肾上腺皮质腺瘤宽体探测器CT灌注成像特点。方法回顾性分析21例经病理证实的肾上腺皮质腺瘤患者的宽体探测器CT扫描资料。CT灌注(CTP)扫描采用16cm探测器覆盖的轴扫模式,ASiR-V50%,注射对比剂6s后开始行CTP数据采集,共采集26期图像,在第22s、51s及153s获取动脉期、静脉期及延迟期增强图像。测量肾上腺腺瘤(A组)和对侧正常肾上腺结合部(B组)的血流量(BF)、血容量(BV)、平均通过时间(MTT)、达峰时间(TP)及表面通透性(PS)值。比较2组间各参数值的差异,并评价辐射剂量。应用ROC曲线分析CT灌注参数对肾上腺腺瘤的诊断效能。结果 A组的BV、MTT及PS值均低于B组(P均<0.05),2组间BF、TP值差异无统计学意义(P均>0.05)。以BV、MTT及PS值诊断肾上腺腺瘤的ROC曲线下面积(AUC)分别为0.780、0.762及0.831,以PS值1.37ml/(100g·min)为阈值诊断腺瘤的敏感度为95.2%,特异度为81.0%。平扫、CTP(含增强三期)的有效辐射剂量(ED)分别为(3.20±0.57)、(19.98±1.95)。结论宽体探测器CT灌注成像可为诊断肾上腺皮质腺瘤提供高质量常规三期强化图像,同时提供有效的定量灌注数据。PS值对腺瘤有较高诊断效能。 Objective To investigate the characteristics of CT perfusion imaging of wide-body adrenocortical adenoma. Methods A retrospective analysis of 21 cases of pathologically confirmed adrenal adenoma in patients with wide-body CT scan data. CT perfusion (CTP) scan using a 16cm detector covered axis scan mode, ASiR-V50%, 6s after injection of contrast agent CTP data acquisition, a total of 26 images were collected at the 22s, 51s and 153s to obtain the arterial phase, Period and delay enhance images. The blood flow (BF), blood volume (BV), mean transit time (MTT), peak time (TP) and surface permeability of adrenal adenoma (group A) and contralateral normal adrenal junction (group B) (PS) value. The differences between the two groups were compared, and the radiation dose was evaluated. Analysis of CT perfusion parameters on the diagnosis of adrenal adenoma using ROC curve. Results The BV, MTT and PS values ​​in group A were lower than those in group B (all P <0.05). There was no significant difference in BF and TP between the two groups (all P> 0.05). The area under the ROC curve (AUC) for diagnosis of adrenal adenomas with BV, MTT and PS values ​​were 0.780, 0.762 and 0.831, respectively. The sensitivity of adenoma with the value of 1.37ml / (100g · min) was 95.2% The specificity was 81.0%. The effective radiation dose (ED) of plain scan and CTP (including enhanced three phases) were (3.20 ± 0.57) and (19.98 ± 1.95), respectively. Conclusion The wide body CT perfusion imaging can provide high-quality conventional three-stage enhanced images for diagnosis of adrenocortical adenoma and provide effective quantitative perfusion data. PS value of adenoma has a higher diagnostic efficacy.
其他文献
目的:分析采用不对称双眼皮整形修复术的临床效果以及满意度情况.方法:从2017年7月~2018年7月选取我院所收治的58例双眼皮不对称整形患者作为本次研究对象,每组各29例采用随机
该研究的目的是从废渣中提取副产物M(2-硫醇基苯并噻唑)和三苯氧膦,这样既减轻了废渣造成的环境污染,又可创造出一定的经济效益.该文确定了从头孢噻肟钠生产废渣中分离提纯M
采用铸锭冶金法制备了6005A合金和含硼有庑硼Al-Mg合金,并采用ER5356和上述两种Al-Mg合金制成的焊丝及T态的6005型材进行了自动熔化极氩弧焊焊接.通过硬度、室温拉伸测定研究
本文通过对荣华二采区10
期刊
近年来,利用能与锂等碱金属离子发生拓扑化学反应的MoO、VO等层状氧化物的层间结构特征,将聚合物嵌入层间来改善界面和层间性质,使材料呈现出许多优异的性能,对这类材料合成
TiB2具有高熔点,高强度和硬度,优良的耐磨性,好的导电性及化学稳定性,与熔融金属良好的润湿性等优异的性能,在高温结构陶瓷材料功能材料复合材料耐火材料航空材料等众多领域有广泛
80后和90后是在质疑声中长大的.他们身上总是贴着“垮掉的一代”的标签,小时候被批评难管教、太叛逆,而长大了则被抨击难管理、爱辞职.
期刊
学位
该文以与城市污水水质相近的人工配液对罗固源教授提出的组合式间歇曝气系统(PIAS:Package Intermittent Aeration System),在原有的脱氮研究基础上,进行了生物除磷脱氮效果