论文部分内容阅读
对于1998年第2期《建筑工人》上刊登的《阳台扶手与墙体连接的方法》一文,我有以下几点意见。1.根据砖砌体水平灰缝要求,灰缝厚度应控制在8~12毫米(根据季节要求,一般常温取10毫米,冬季取8毫米)。为保证砌体内所埋设的钢筋不被腐蚀,钢筋上下至少应各有2毫米厚的砂浆层。因此,埋设直径10毫米的钢筋偏大,一般来讲还是用φ6.5~8钢筋为宜,预埋钢筋应设置在扶手位置处上下3皮砖的灰缝内,上下各2根,伸
For the article “Method of Connecting Handrails and Walls of Balconies” published in “Construction Workers” in the second issue of 1998, I have the following points. 1. According to the requirement of horizontal masonry mortar joints, the thickness of the mortar joints should be controlled within 8-12mm (according to the season requirements, generally 10mm at normal temperature and 8mm in winter). In order to ensure that the steel bars buried in the masonry are not corroded, the steel bars should have at least 2 mm thick mortar layers above and below. Therefore, the embedding of a steel bar with a diameter of 10 mm is somewhat large. In general, it is preferable to use φ6.5 to 8.0 steel bars. The embedded steel bar should be set in the ash seam of the upper and lower 3 tiles at the position of the handrail.