论文部分内容阅读
患者男,42岁,外包检修电工。1994年12月工作时擅自到厂房400伏动力盘上接电源,不慎其金属眼睛眶架碰到动力盘三相保险中的二相保险上,产生电弧光将其击倒在地。现场工人立即断电,将其移卧于安全地区,因其不语即用人工心肺复苏法进行抢救,同时电话求救医护人员于10分钟赶到。查体:T 37℃,P
Male patient, 42 years old, outsourced overhaul electricians. Worked in December 1994 without permission to the plant 400-volt power plate on the power supply, accidentally touched the metal eye orbital frame power disc three-phase insurance in the two-phase insurance, resulting in the arc knocked it to the ground. The workers in the field immediately cut off their electricity and moved them to a safe area. Because of their lack of words, they were rescued by the artificial cardiopulmonary resuscitation (CPR) method. At the same time, the emergency medical staff arrived by telephone in 10 minutes. Physical examination: T 37 ℃, P.