论文部分内容阅读
AIM:To investigate the diagnostic capability of breathhold diffusion-weighted imaging(DWI) for differentiation between malignant and benign hepatic lesions.METHODS:A total of 614 malignant liver lesions(132 hepatocellular carcinomas,468 metastases and 14 intrahepatic cholangiocarcinomas) and 291 benign liver lesions(102 hemangiomas,158 cysts,24 focal nodular hyperplasia,1 angiomyolipoma and 6 hepatic adenomas) were included from seven studies(eight sets of data).RESULTS:The pooled sensitivity and specificity of breath-hold DWI were 0.93 [95% confidence interval(CI):0.91-0.95] and 0.87(95%CI:0.83-0.91),respectively.The positive likelihood ratio and negative likelihood ratio were 7.28(95%CI:4.51-11.76) and 0.09(95%CI:0.05-0.17),respectively.The P value for χ2 heterogeneity for all pooled estimates was < 0.05.From the fitted summary receiver operating characteristic curve,the area under the curve and Q * index were 0.96 and 0.91,respectively.Publication bias was not present(t = 0.49,P = 0.64).The meta-regression analysis indicated that evaluated covariates including magnetic resonance imaging modality,echo time,mean age,maximum b factor,and number of b factors were not sources of heterogeneity(all P > 0.05).CONCLUSION:Breath-hold DWI is useful for differentiating between malignant and benign hepatic lesions.The diffusion characteristics of benign lesions that mimic malignant ones have rarely been investigated.
AIM: To investigate the diagnostic capability of breathhold diffusion-weighted imaging (DWI) for differentiation between malignant and benign hepatic lesions. METHODS: A total of 614 malignant liver lesions (132 hepatocellular carcinomas, 468 metastases and 14 intrahepatic cholangiocarcinomas) and 291 benign liver The lesions (102 hemangiomas, 158 cysts, 24 focal nodular hyperplasia, 1 angiomyolipoma and 6 hepatic adenomas) were included from seven studies (eight sets of data) .RESULTS: The pooled sensitivity and specificity of breath-hold DWI were 0.93 [95% confidence (95% CI: 0.83-0.91), respectively. The positive likelihood ratio and negative likelihood ratio were 7.28 (95% CI: 4.51-11.76) and 0.09 -0.17), respectively. P value for χ2 heterogeneity for all pooled estimates was <0.05. From the fitted summary receiver operating characteristic curve, the area under the curve and Q * index were 0.96 and 0.91, respectively. Publications bias was not present (t = 0.49, P = 0.64). The meta-regression analysis indicated that evaluated covariates including magnetic resonance imaging modality, echo time, mean age, maximum b factor, and number of b factors were not sources of heterogeneity (all P> 0.05) .CONCLUSION: Breath-hold DWI is useful for differentiating between malignant and benign hepatic lesions. The diffusion characteristics of benign lesions that mimic malignant ones have rarely been investigated.