介绍了《工业循环水冷却设计规范》(GB/T50102—2003)和《火力发电厂水工设计规范》(DL/T5339—2006)中冷却塔静风局部稳定检算方法——屈曲临界应力状态的公式来源、试验背景以及参数取值原则等,便于设计研究人员正确理解和应用局部稳定检算公式。根据Mungan针对圆柱壳、双曲壳以及加劲双曲壳的一系列试验及与其他国家规范的比较,指出了现行规范中相关条款的缺陷,为规范条款的修订和完善提供了参考。
The method for calculating the local stability of the cooling tower static wind in the “Design Code for Industrial Recycled Water Cooling” (GB / T50102-2003) and “Code for Design of Thermal Power Plant Hydraulic Engineering” (DL / T5339-2006) is introduced - the critical buckling state The source of the formula, the background of the experiment and the principle of the parameter values, so as to facilitate the design and research personnel to correctly understand and apply the local stability detection formula. According to Mungan’s series of tests on cylindrical shells, hyperbolic shells and stiffened hyperbolic shells and comparison with other national norms, the shortcomings of relevant clauses in current codes were pointed out, which provided references for the revision and improvement of the regulation clauses.