论文部分内容阅读
报道了利用3km 光纤非线性环镜作为全光解复用器对8×25Gb/s光时分复用信号的解复用实验结果, 并对25Gb/s解复用信号进行了误码特性的测量。测量结果表明误码率可达到10- 11, 误码率为10- 9时的功率代价仅为14dB。
The experimental results on the demultiplexing of 8 × 25Gb / s optical time-division multiplexed signals using 3km optical fiber non-linear ring mirror as the all-optical demultiplexer are reported, and the error of 25Gb / s demultiplexing signals Measurement of code characteristics. The measurement results show that the bit error rate can reach 10-11, the bit error rate of 10-9 when the power cost is only 1 4dB.