论文部分内容阅读
【摘 要】静态破碎技术具有无震动、无冲击波、无飞石等优点,近年来已广泛应用于破碎坚硬岩石和拆除各种混凝土施工中。本文以平昌县某边坡危岩处治工程为例,介绍静态破碎的各项设计参数,分析施工成本,同时指出了使用该技术的局限性。
【关键词】静态破碎剂;设计参数;边坡;危岩
Static Breaking Technology In Dangerous rock Control Project Application
Liu De-bing1,2,Tan Chun-yang2,Chen Guang-jian2, Li Yi2
(1.No. 137 Geological Team , Sichuan Bureau of Coal Geology Dazhou Sichuan 635006;
2.Sichuan Shudong Geological Investigation Design & Research Institute Dazhou Sichuan 635006)
【Abstract】The static breaking technology has without the vibration, stone merits and so on does not have the shock-wave, not flies, in recent years widely has applied in the stave hard rock and demolishes in each kind of concrete construction. In this paper, Pingchang project as an example of a steep slope dangerous rock control, introduced the static state stave each design parameters, the analysis construction cost, had simultaneously pointed out uses this technical the limitation.
【Key words】Soundless Cracking Agent;Design Parameters;Slope;Dangerous Rock
1. 引言
静态破碎是20世纪80年代末至90年代初兴起的一种新型爆破开挖技术,魏承景,谢逢午[1 ],冯彧雷[2 ],张爱莉,姚刚[3 ]等已对其进行了一定的研究。静态破碎就是利用静态破碎剂(英文名:Soundless Cracking Agent,简称SCA,也称无声炸药、破石剂、裂石剂)水化后,体积大量膨胀对孔壁产生径向压力,当径向压力在孔壁切向上引起的拉应力大于岩石的抗拉强度时,岩石就被破碎[1-3 ]。与普通爆破技术相比,静态破碎技术具有安全、无噪音、无震动、无飞石、无硝烟,无污染、不影响周围环境及安全性高等诸多优点。基于这些优点,该技术也被应用于抗滑桩坚硬岩石开挖中[4 ]。
目前,对该技术在危岩处治中的应用、施工成本分析以及应用的局限性论述较少。本文以四川平昌县金佛望江名都住宅小区边坡危岩治理工程为例,介绍静态破碎的各项设计参数选取,分析其施工成本,为该技术在类似的危岩工程治理中的应用提供参考。
2. 工程概况
平昌县金佛望江名都住宅小区边坡高陡,连绵分布长约400m,坡高20~35m,坡度70~90°,为反向斜坡,边坡下方过境的S202省道为平昌城区繁华路段。区内分布地层主要有第四系人工填土(Q4me)和坡残积层(Q4el+dl)以及侏罗系上统蓬莱镇组(J3p)地层。据调查访问,近年来该路段曾多次发生崩塌落石,造成人员伤害、财产损失。受“5•12”汶川地震影响,该段边坡危岩变形有所加剧,稳定性进一步降低[5 ]。边坡上下方原有建筑多临崖而建,危岩一旦发生崩塌,将严重威胁到这些房屋和下方的车辆、行人的安全,并将给社会稳定和居民生产生活带来极严重影响。
在该危岩处治工程中,典型危岩体WY7高约17m、厚约7m、长约20m,体积约2380m3;WY8危岩体位于WY7外侧,高约17.5m、厚约6.5m、长约24m,体积约2730m3,见图1照片1。危岩体立于斜坡上部,岩性为巨厚层砂岩,层面近水平,产状为230°∠3°,节理裂隙较发育,少量泥质填充。危岩体平面呈不规则体四边形,立面为块状,局部临空外悬,可能产生滑塌式破坏,必须进行清除、排危处理,见图2。
由于WY7、WY8危岩体距离下方建筑和S202省道较近,无法采用常规的爆破方法进行施工,为保证施工安全和施工进度,在该边坡危岩处治施工中采用了静态破碎技术,效果较好。
3. 破碎剂选择
目前国内生产的静态破碎剂种类很多,不同厂家、不同种类、不同规格型号、不同批次、不同比例的反应时间和膨胀率都不一样[3-4 ]。本工程选用的四川省珙县建洪化工厂生产的“超力牌”静态破碎剂,该产品为浅灰白色粉末,具有膨胀力大、反应时间短等特点。经相关文献[1-3 ]统计,其最大膨胀力约122MPa,最大膨胀力出现最短时间为10min。
图1照片1清除前典型危岩体WY7、WY8
图2 典型危岩体WY8剖面示意图
4. 设计参数
4.1 孔距与排距布置
静态破碎钻孔的孔距、排距的大小与岩石硬度、混凝土强度及钢筋布置有直接关系,硬度越大、混凝土强度越高、布筋越密、钢筋越粗时,孔距与排距越小,反之则大。孔距、排距与破碎介质类别或硬度关系见图3所示,图中“F”为岩石普氏硬度系数。
图3孔距、排距与破碎介质关系示意图
据勘查[6 ],危岩属坚固砂岩,参照岩石硬度等级划分标准(见表1),岩石级别为IIIa,普氏硬度系数F=8。本工程选用的“超力牌”静态破碎剂布孔相关设计参数见表2。综合考虑拟清除危岩体的临空面情况,选取孔距为30cm,排距为30~40cm,钻孔成梅花形交错布置。
采用“从上到下,由外及里”的施工顺序,呈台阶状分级、分层清除危岩体。由于静态破碎剂对危岩的破坏作用只是产生若干裂缝,岩石碎块依靠这些裂缝啮合在一起仍很紧密,因此不能直接清除,需用风镐配合将岩石破碎松散后才能进行。危岩体破碎后的块石截面大致为0.3×0.3m,质量较好的可供砌石工程使用。
图4 分层破碎后的孔深及孔距痕迹
图5 危岩体在装药后逐渐开裂破碎
4.2 钻孔直径及深度。
钻孔直径与危岩体破碎效果有直接关系,钻孔过小,不利于破碎剂充分发挥效力;钻孔太大,易造成冲孔。本工程取直径为40mm的钻头,采用风钻成孔。钻孔深度根据危岩体裂隙发育情况确定,取1.0~1.5m,见图4。
4.3 装药破碎。
装药深度为孔深的100%。装药前用高压风将钻孔内余水、余渣吹洗干净,孔口旁清理干净至无土石渣后,将破碎剂加重量比为30%的水拌成流质状(充分搅拌后略有余水),迅速倒入孔内并用略小于钻孔的木棍捣固密实。在危岩体开裂后,立即向裂缝中加水,以支持破碎剂持续反应。
根据施工现场条件,反应时间控制在30~45min,以便在危岩体上的施工人员撤离至安全地带。通过现场观察,危岩体在装药后40min左右开裂,在3h左右基本达到破碎目的,见图5。
破碎剂反应的快慢与温度有直接的关系,温度越高,反应时间越快,反之则慢。实际操作中,控制药剂反应时间太快的方法有两种,一种是在拌合水中加入抑制剂。另一种方法是严格控制拌和水、干粉药剂和岩石(或混凝土)的温度。
气温较低,药剂反应时间会相应延长,一般解决办法是加入促发剂和提高拌和水温度。促发剂加入过多,也会降低药剂膨胀力。拌和水温可根据实际适当提高,但最高不可超过50℃。
5. 安全措施
5.1 设置安全警戒线,严禁无关人员入内。在S202省道内侧搭设多排钢管防护架,并在防护架内侧地面铺设松散土方做落石缓冲层。
5.2 冲孔现象是不可预见和不可完全控制的。为防止伤人事故,操作人员必须戴符合国家安全标准生产的防冲击防尘PVC护目镜进行操作。在药剂灌入钻孔到岩石或混凝土开裂前,不可将面部直接近距离面对已装药的钻孔。药剂灌装完成后,盖上麻袋或棕垫,远离装灌点。
5.3 刚钻完孔和刚冲孔的钻孔,孔壁温度较高,应确定温度正常符合要求并清洗干净后才能继续装入破碎剂[7 ]。
6. 结语
6.1 实践证明,本工程所采取静态破碎的施工工艺、施工方法和技术处理措施,能够保证城区繁华路段危岩处治的施工安全以及施工进度,对类似工程具有一定的借鉴意义。
6.2 经笔者测算,采用静态破碎的成本约为45~55元/m3,远远低于危岩处治工程中传统的人工凿石排危施工成本(约120~180元/m3),但也高于普通爆破(明爆)作业成本(约20~30元/m3),实际工程中应选择性使用。
6.3 静态破碎是不方便使用炸药的情况下破碎岩石、混凝土的新方法,静态破碎剂的膨胀作用原理决定其只能利用、创造临空面,密集钻孔,分批破碎。静态破碎是控制爆破的发展和补充,有其使用的局限性,比如:混凝土内钢筋粗、密、呈笼状布列的构件,不宜采用静态破碎;巷道、宽深比<1.0的沟槽开挖、临空面不理想的地方,以及高耸构件拆除等,都不宜采用静态破碎。
6.4 针对静态破碎剂的使用受温度影响较大的特点,为方便使用和提高破碎效果,建议相关厂家实行“温度订制式”生产,根据各地气温及需破碎材质的不同,配制出适合各地、各工程材料使用的、更具针对性、效果更好的产品。
参考文献
[1] 魏承景,谢逢午.静态破碎技术[M],南宁,广西科技出版社,1989.
[2] 冯彧雷.静态破碎技术的研究[J],黑龙江科技信息,2010,(4):23.
[3] 张爱莉,姚刚.静态爆破的设计及应用[J],建筑技术,2002,33(6):420-422.
[4] 亢会明,刘涛,张建良.静态破碎剂在抗滑桩坚硬岩石开挖中的应用[J],施工技术,2004,33(9).
[5] 四川蜀东地质勘察设计研究院,平昌县望江名都住宅小区边坡危岩治理工程施工图设计[R],2009.
[6] 四川煤田地质一三七总公司,平昌县金佛望江明都花园场地工程地质勘察报告[R],2005.
[7] 刘键.静态爆破研究、爆破与安全[M],武汉,湖北科技出版社,1984.
[文章编号]1619-2737(2011)04-09-81
[作者简介] 刘德兵(1977-),男,籍贯:四川岳池人,学历:本科,职称:工程师,主要从事地质灾害勘查、评价与防治技术研究工作。
注:本文中所涉及到的图表、注解、公式等内容请以PDF格式阅读原文
【关键词】静态破碎剂;设计参数;边坡;危岩
Static Breaking Technology In Dangerous rock Control Project Application
Liu De-bing1,2,Tan Chun-yang2,Chen Guang-jian2, Li Yi2
(1.No. 137 Geological Team , Sichuan Bureau of Coal Geology Dazhou Sichuan 635006;
2.Sichuan Shudong Geological Investigation Design & Research Institute Dazhou Sichuan 635006)
【Abstract】The static breaking technology has without the vibration, stone merits and so on does not have the shock-wave, not flies, in recent years widely has applied in the stave hard rock and demolishes in each kind of concrete construction. In this paper, Pingchang project as an example of a steep slope dangerous rock control, introduced the static state stave each design parameters, the analysis construction cost, had simultaneously pointed out uses this technical the limitation.
【Key words】Soundless Cracking Agent;Design Parameters;Slope;Dangerous Rock
1. 引言
静态破碎是20世纪80年代末至90年代初兴起的一种新型爆破开挖技术,魏承景,谢逢午[1 ],冯彧雷[2 ],张爱莉,姚刚[3 ]等已对其进行了一定的研究。静态破碎就是利用静态破碎剂(英文名:Soundless Cracking Agent,简称SCA,也称无声炸药、破石剂、裂石剂)水化后,体积大量膨胀对孔壁产生径向压力,当径向压力在孔壁切向上引起的拉应力大于岩石的抗拉强度时,岩石就被破碎[1-3 ]。与普通爆破技术相比,静态破碎技术具有安全、无噪音、无震动、无飞石、无硝烟,无污染、不影响周围环境及安全性高等诸多优点。基于这些优点,该技术也被应用于抗滑桩坚硬岩石开挖中[4 ]。
目前,对该技术在危岩处治中的应用、施工成本分析以及应用的局限性论述较少。本文以四川平昌县金佛望江名都住宅小区边坡危岩治理工程为例,介绍静态破碎的各项设计参数选取,分析其施工成本,为该技术在类似的危岩工程治理中的应用提供参考。
2. 工程概况
平昌县金佛望江名都住宅小区边坡高陡,连绵分布长约400m,坡高20~35m,坡度70~90°,为反向斜坡,边坡下方过境的S202省道为平昌城区繁华路段。区内分布地层主要有第四系人工填土(Q4me)和坡残积层(Q4el+dl)以及侏罗系上统蓬莱镇组(J3p)地层。据调查访问,近年来该路段曾多次发生崩塌落石,造成人员伤害、财产损失。受“5•12”汶川地震影响,该段边坡危岩变形有所加剧,稳定性进一步降低[5 ]。边坡上下方原有建筑多临崖而建,危岩一旦发生崩塌,将严重威胁到这些房屋和下方的车辆、行人的安全,并将给社会稳定和居民生产生活带来极严重影响。
在该危岩处治工程中,典型危岩体WY7高约17m、厚约7m、长约20m,体积约2380m3;WY8危岩体位于WY7外侧,高约17.5m、厚约6.5m、长约24m,体积约2730m3,见图1照片1。危岩体立于斜坡上部,岩性为巨厚层砂岩,层面近水平,产状为230°∠3°,节理裂隙较发育,少量泥质填充。危岩体平面呈不规则体四边形,立面为块状,局部临空外悬,可能产生滑塌式破坏,必须进行清除、排危处理,见图2。
由于WY7、WY8危岩体距离下方建筑和S202省道较近,无法采用常规的爆破方法进行施工,为保证施工安全和施工进度,在该边坡危岩处治施工中采用了静态破碎技术,效果较好。
3. 破碎剂选择
目前国内生产的静态破碎剂种类很多,不同厂家、不同种类、不同规格型号、不同批次、不同比例的反应时间和膨胀率都不一样[3-4 ]。本工程选用的四川省珙县建洪化工厂生产的“超力牌”静态破碎剂,该产品为浅灰白色粉末,具有膨胀力大、反应时间短等特点。经相关文献[1-3 ]统计,其最大膨胀力约122MPa,最大膨胀力出现最短时间为10min。
图1照片1清除前典型危岩体WY7、WY8
图2 典型危岩体WY8剖面示意图
4. 设计参数
4.1 孔距与排距布置
静态破碎钻孔的孔距、排距的大小与岩石硬度、混凝土强度及钢筋布置有直接关系,硬度越大、混凝土强度越高、布筋越密、钢筋越粗时,孔距与排距越小,反之则大。孔距、排距与破碎介质类别或硬度关系见图3所示,图中“F”为岩石普氏硬度系数。
图3孔距、排距与破碎介质关系示意图
据勘查[6 ],危岩属坚固砂岩,参照岩石硬度等级划分标准(见表1),岩石级别为IIIa,普氏硬度系数F=8。本工程选用的“超力牌”静态破碎剂布孔相关设计参数见表2。综合考虑拟清除危岩体的临空面情况,选取孔距为30cm,排距为30~40cm,钻孔成梅花形交错布置。
采用“从上到下,由外及里”的施工顺序,呈台阶状分级、分层清除危岩体。由于静态破碎剂对危岩的破坏作用只是产生若干裂缝,岩石碎块依靠这些裂缝啮合在一起仍很紧密,因此不能直接清除,需用风镐配合将岩石破碎松散后才能进行。危岩体破碎后的块石截面大致为0.3×0.3m,质量较好的可供砌石工程使用。
图4 分层破碎后的孔深及孔距痕迹
图5 危岩体在装药后逐渐开裂破碎
4.2 钻孔直径及深度。
钻孔直径与危岩体破碎效果有直接关系,钻孔过小,不利于破碎剂充分发挥效力;钻孔太大,易造成冲孔。本工程取直径为40mm的钻头,采用风钻成孔。钻孔深度根据危岩体裂隙发育情况确定,取1.0~1.5m,见图4。
4.3 装药破碎。
装药深度为孔深的100%。装药前用高压风将钻孔内余水、余渣吹洗干净,孔口旁清理干净至无土石渣后,将破碎剂加重量比为30%的水拌成流质状(充分搅拌后略有余水),迅速倒入孔内并用略小于钻孔的木棍捣固密实。在危岩体开裂后,立即向裂缝中加水,以支持破碎剂持续反应。
根据施工现场条件,反应时间控制在30~45min,以便在危岩体上的施工人员撤离至安全地带。通过现场观察,危岩体在装药后40min左右开裂,在3h左右基本达到破碎目的,见图5。
破碎剂反应的快慢与温度有直接的关系,温度越高,反应时间越快,反之则慢。实际操作中,控制药剂反应时间太快的方法有两种,一种是在拌合水中加入抑制剂。另一种方法是严格控制拌和水、干粉药剂和岩石(或混凝土)的温度。
气温较低,药剂反应时间会相应延长,一般解决办法是加入促发剂和提高拌和水温度。促发剂加入过多,也会降低药剂膨胀力。拌和水温可根据实际适当提高,但最高不可超过50℃。
5. 安全措施
5.1 设置安全警戒线,严禁无关人员入内。在S202省道内侧搭设多排钢管防护架,并在防护架内侧地面铺设松散土方做落石缓冲层。
5.2 冲孔现象是不可预见和不可完全控制的。为防止伤人事故,操作人员必须戴符合国家安全标准生产的防冲击防尘PVC护目镜进行操作。在药剂灌入钻孔到岩石或混凝土开裂前,不可将面部直接近距离面对已装药的钻孔。药剂灌装完成后,盖上麻袋或棕垫,远离装灌点。
5.3 刚钻完孔和刚冲孔的钻孔,孔壁温度较高,应确定温度正常符合要求并清洗干净后才能继续装入破碎剂[7 ]。
6. 结语
6.1 实践证明,本工程所采取静态破碎的施工工艺、施工方法和技术处理措施,能够保证城区繁华路段危岩处治的施工安全以及施工进度,对类似工程具有一定的借鉴意义。
6.2 经笔者测算,采用静态破碎的成本约为45~55元/m3,远远低于危岩处治工程中传统的人工凿石排危施工成本(约120~180元/m3),但也高于普通爆破(明爆)作业成本(约20~30元/m3),实际工程中应选择性使用。
6.3 静态破碎是不方便使用炸药的情况下破碎岩石、混凝土的新方法,静态破碎剂的膨胀作用原理决定其只能利用、创造临空面,密集钻孔,分批破碎。静态破碎是控制爆破的发展和补充,有其使用的局限性,比如:混凝土内钢筋粗、密、呈笼状布列的构件,不宜采用静态破碎;巷道、宽深比<1.0的沟槽开挖、临空面不理想的地方,以及高耸构件拆除等,都不宜采用静态破碎。
6.4 针对静态破碎剂的使用受温度影响较大的特点,为方便使用和提高破碎效果,建议相关厂家实行“温度订制式”生产,根据各地气温及需破碎材质的不同,配制出适合各地、各工程材料使用的、更具针对性、效果更好的产品。
参考文献
[1] 魏承景,谢逢午.静态破碎技术[M],南宁,广西科技出版社,1989.
[2] 冯彧雷.静态破碎技术的研究[J],黑龙江科技信息,2010,(4):23.
[3] 张爱莉,姚刚.静态爆破的设计及应用[J],建筑技术,2002,33(6):420-422.
[4] 亢会明,刘涛,张建良.静态破碎剂在抗滑桩坚硬岩石开挖中的应用[J],施工技术,2004,33(9).
[5] 四川蜀东地质勘察设计研究院,平昌县望江名都住宅小区边坡危岩治理工程施工图设计[R],2009.
[6] 四川煤田地质一三七总公司,平昌县金佛望江明都花园场地工程地质勘察报告[R],2005.
[7] 刘键.静态爆破研究、爆破与安全[M],武汉,湖北科技出版社,1984.
[文章编号]1619-2737(2011)04-09-81
[作者简介] 刘德兵(1977-),男,籍贯:四川岳池人,学历:本科,职称:工程师,主要从事地质灾害勘查、评价与防治技术研究工作。
注:本文中所涉及到的图表、注解、公式等内容请以PDF格式阅读原文