某电厂2×330 MW两台亚临界锅炉自2012年下半年以来连续在同一位置发生三次末级过热器爆管事故(累计运行仅3万小时/台),造成了很大经济损失。该厂为查明原因做了大量工作,检查Ⅱ级喷水减温器、末级过热器入口联箱与管子(异物和氧化皮)、管材等均未发现异常,使爆管原因分析工作陷入困境。本研究从运行调整入手,通过对大量运行参数和末级过热器入口联箱结构展开深入分析,得出这几次事故是在特定条件下氧化皮短时大量脱落造成爆管的结论,并制定出针对性预防措施。
A 2 × 330 MW two subcritical boilers of a power plant have suffered from three consecutive superheater bursts (three decades of cumulative operation) in a row at the same location since the second half of 2012, resulting in significant economic losses. The factory has done a lot of work to find out the reason, check Ⅱ level water jet desuperheater, superheater inlet header and tube (foreign matter and oxide scale), pipe and so on were found no exception, the pipe burst analysis into work Dilemma. In this paper, starting with the adjustment of operation, through in-depth analysis of a large number of operating parameters and final inlet structure of the superheater, it is concluded that these accidents are caused by a large number of oxide scales breaking off in a short time under certain conditions, A targeted preventive measures.