Localization and characterization of intermittent pollutant source in buildings with ventilation sys

来源 :建筑模拟(英文版) | 被引量 : 0次 | 上传用户:yp0202
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Terrorist attacks through building ventilation systems are becoming an increasing concern. In case polutants are intentionally released in a building with mechanical ventilation systems, it is critical to localize the source and characterize its releasing curve. Previous inverse modeling studies have adopted the adjoint probability method to identify the source location and used the Tikhonov regularization method to determine the source releasing profile, but the selection of the prediction model and determination of the regularization parameter remain challenging. These limitations can affect the identification accuracy and prolong the computational time required. To address the difficulties in solving the inverse problems, this work proposed a Markov-chain-oriented inverse approach to identify the temporal release rate and location of a pollutant source in buildings with ventilation systems and validated it in an experimental chamber. In the modified Markov chain, the source term was discrete by each time step, and the polutant distribution was directly calculated with no iterations. The forward Markov chain was reversed to characterize the intermittently releasing profile by introducing the Tikhonov regularization method, while the regularized parameter was determined by an automatic iterative discrepancy method. The source location was further estimated by adopting the Bayes inference. With chamber experiments, the effectiveness of the proposed inverse model was validated, and the impact of the sensor performance, quantity and placement, as wel as polutant releasing curves on the identification accuracy of the source intensity was explicitly discussed. Results showed that the inverse model can identify the intermittent releasing rate efficiently and promptly, and the identification error for pollutant releasing curves with complex waveforms is about 20%.
其他文献
Curtain walls are more and more commonly used as building facades. They allow a better daylight availability and a direct connection to exterior environments. M
In countries suffering from heavy ambient air pollution, ventilation is a problem, as ventilation intakes outdoor air pollutants, such as particulate matter wit
The design of urban squares in the city of Mendoza, Argentina, is based on aesthetic and landscaping criteria without consider strategies to enhance the benefit
The conventional control methods of variable air volume (VAV) air conditioning systems usually assume that the indoor air is well mixed, and consider each build
Global urbanization causes more environmental stresses in cities and energy efficiency is one of major concerns for urban sustainability. The variable importanc
Large space circular coal storage dome (LSCCSD) offers an environmental and dependable alternative to open stockpiles, and it has been consequently widely appli
This paper has analyzed the asymmetric flow effect of fire-induced thermal flow in a horizontal tunnel under the natural ventilation condition by conducting lar
本文简要阐述了国有大型集团公司管理现状,分析了国有大型集团公司对下属子公司管理的主要模式和存在的主要问题,并以此为依据,提出了在“大”框架内“细而实”、在“小”的基础上“统而整”,实现“活”和“合”有机统一的国有大型集团公司管理模式的建议。
Buildings represent a large part in terms of fossil energy consumption, which depends on the great need for heating. Even if the solar absorption heat storage s
A good skylight environment in urban residential areas is an important component of a healthy city, and has always been highly valued. With the rapid developmen