论文部分内容阅读
目的:评价卡式尿素[n 14C]呼气试验药盒、闪烁采样瓶(固体闪烁法)、液体闪烁式(以下简称液闪式)尿素[n 14C]呼气试验药盒诊断幽门螺杆菌(n H.n pylori)感染的效果。n 方法:纳入2020年1月7日至10月28日在上海交通大学医学院附属仁济医院、浙江大学医学院附属第二医院、南昌大学第一附属医院就诊的239例患者。所有受试者均先接受n 14C尿素呼气试验,气体收集结束后>1~1 to <7 days after gas collection, mucosal tissues were taken under gastroscopy for gold standard test, including biopsy and rapid urease test (RUT). If both biopsy and RUT indicated n H. n pylori positive, the result of gold standard test was n H. n pylori positive, and if both were negative, the result of gold standard test was n H. n pylori negative. If the results of biopsy and RUT were inconsistent, they were not included in the subsequent analysis. Based on the results of gold standard test, the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of the cassette n 14C-urea breath test kit, scintillation sampling bottle, and liquid scintillation n 14C-urea breath test kit in the diagnosis of n H. n pylori infection were analyzed. The safety of the test was evaluated by whether there were any adverse events during the test. Descriptive methods were used for statistical analysis.n Results:Among the 239 subjects, 12 cases did not complete the test, 227 subjects finally completed the test. The test completion rate was 95.0% (227/239). No.008 patient was only included in the analysis of cassette n 14C-urea breath test kit and scintillation sampling bottle because of lacking the result of liquid scintillation breath test. The results of gold standard test showed that among 227 patients, 87 cases were n H. n pylori positive, 118 cases were n H. n pylori negative. The results of biopsy and RUT were inconsistent in 22 cases, so they were not included in the subsequent analysis. Excluding No.008 patient, the results of gold standard test showed that 86 cases were n H. n pylori positive and 118 cases were negative. Based on the results of gold standard test, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of cassette n 14C-urea breath test kit, scintillation sampling bottle, and the liquid scintillation n 14C-urea breath test kit in the diagnosis of n H. n pylori infection were 91.9%, 100.0%, 96.6%, 100.0% and 94.4%, respectively; 95.4%, 97.5%, 96.6%, 96.5% and 96.6%, respectively; and 96.5%, 99.2%, 98.0%, 98.8% and 97.5%, respectively. Only one adverse event (right upper abdominal pain after eating) occurred. Combined with the patients condition, the adverse event was determined as the onset of chronic cholecystitis and it might not be related to the test medication.n Conclusions:Cassette n 14C-urea breath test kit, scintillation sampling bottle, and liquid scintillation n 14C-urea breath test kit have reliable performance, good safety, and high sensitivity, specificity and accuracy in the diagnosis of n H. n pylori infection, which are worthy of clinical application.n