我站装有四台容量为5000kW的立式水轮发电机组,励磁机型号为ZLS59/17-6,额定电压132V,额定电流468A,额定功率61.8kW,电枢绕组为双波绕组。机组投产三年多来,励磁机各方面都正常,但在励磁机定子线圈、电枢线圈表面及缝隙中填满了与油混合成一体的炭粉,测量励磁机电枢线圈的绝缘电阻在0.3MΩ以下,以致机组不能运转。励磁机炭刷和换向器相互摩擦,不断有炭粉和铜屑掉落,并与推力轴承(上导油槽)中溢出的油混合,在离心力和风的作用下,附着在励磁机电枢绕组的缝隙中,当机组满负荷而温度较高时,则推力轴承中溢出更多的油、汽和落下的炭粉混合,使附着力
I stand equipped with four capacity of 5000kW vertical hydro-generator, exciter model ZLS59 / 17-6, rated voltage 132V, rated current 468A, rated power 61.8kW, armature winding for the double-wave winding. Unit put into operation more than three years, all aspects of the exciter are normal, but in the exciter stator coils, armature coil surface and the gap filled with oil mixed into one of the carbon powder, measuring exciter armature coil insulation resistance 0.3 MΩ or less, so that the unit can not operate. The exciter carbon brush and commutator rub each other, there are constantly falling carbon powder and copper scrap, and with the thrust bearing (the upper oil tank) mixed with oil overflow, under the action of centrifugal force and wind, attached to the exciter armature winding In the gap, when the unit is full and the temperature is high, more oil, steam and falling carbon powder will be mixed in the thrust bearing to make the adhesion