为了提高送风系数,笔者在独头巷道作了大量试验。对风筒接头形式作了改进,同时节长加大到20米。论文对各种试验结果作了对比:插接接头,节长为10米,送风系数为46%;粘接方式,节长增到20米,采用插接及胶粘两种接头,则送风系数提高到75%;如改为活单环接头,则效果更好,送风系数可达89%。据此,不仅可减少一台局扇,且大大延长了送风距离,降低了生产成本、提高了经济效益。
In order to improve the air supply coefficient, I made a lot of tests in the single lane. The form of the air tube connector has been improved, while festival length increased to 20 meters. The paper compares the results of various tests: the plug connector, the length of 10 meters, the air supply coefficient of 46%; bonding methods, section length increased to 20 meters, the use of plug and glue two joints, then send Wind factor increased to 75%; If replaced by a single loop connector, the effect is better, the air supply coefficient up to 89%. Accordingly, it can not only reduce the number of one office fan, but also greatly extend the air supply distance, reduce the production cost and increase the economic benefits.