我厂配30万瓩机组的935吨/时直流锅炉再热器的工作参数为:进口——35公斤/厘米~2、337℃C;出口——大于33公斤/厘米~2、570℃。再热器的进、出口联箱上有一列大口径开孔,并焊上支管,构成焊接三通。由于这一列大口径孔间节距较小,导致联箱强度减弱。为了确保机组的安全运行,对这种焊接三通进行了应力测定。试验目的试验是在一只双三通(图1)上进行测定的,其目的主要有下:
I plant with 300,000 units of 935 tons / hour DC boiler reheater operating parameters: import - 35 kg / cm ~ 2,337 ℃ C; exports - more than 33 kg / cm ~ 2,570 ℃. Reheater inlet and outlet header box has a large diameter openings, and welded on the branch, constitute the welding tee. Due to the small diameter of the large aperture between the columns, resulting in reduced strength of the header. In order to ensure the safe operation of the unit, the stress of the welding tee was measured. The purpose of the test The test is carried out in a double three links (Figure 1), the main purpose of the following: