焊条药皮中吸收的水分是手工电弧焊时氢的主要来源之一,氢可以导致钢焊件脆化、开裂和产生气孔。多年来控制焊条药皮中水分含量的有效方法是在焊条使用之前进行严格的烘干,并限定焊条暴露于空气中的时间。例如,美国焊接学会标准(AWSD1.1)规定,对于50kg级的低氢焊条在空气中允许的最长暴露时间为4h。这样在很多现场施工的情况下,焊工只得携带电热的焊条保温筒,以保证他们从烘箱中取出
The moisture absorbed by the electrode coating is one of the major sources of hydrogen during manual arc welding. Hydrogen can cause embrittlement, cracking and porosity in steel weldments. An effective method of controlling the moisture content of electrode coatings over many years is to rigorously dry the electrode before it is used and to limit the time it takes for the electrode to be exposed to the air. For example, the American Welding Society standard (AWSD 1.1) states that the maximum allowable exposure time in air for a 50 kg grade of low-hydrogen electrode is 4 h. In the case of many on-site construction, the welder would only have to carry the heated electrode insulation to ensure that they were removed from the oven