论文部分内容阅读
Simulation on the degradation of 4H-SiC Schottky detector was carried out using ISE TCAD, and the limit of the drift-diffusion analytical model was discussed. Two independent defect levels, rather than a pair of specific carrier lifetime, were induced to describe Z1/2 defects in simulation to calculate the charge collection efficiency versus bias voltage. Comparison between our calculation and the reported experimental results shows that an acceptable agreement was achieved, proving the feasibility of regarding Z1/2 defect as two individual defect levels. Such a treatment can simplify the simulation and may help to further investigate the detector degradation.