论文部分内容阅读
我院自1988年5月以来采用苏州医疗器械厂生产的YD—5型轻便造热电凝器,对鼻中隔前下部反复性鼻出血病人行粘膜表面透热电凝治疗,报告如下。临床资料 观察对象60例,其中右侧26例,左侧31例,双侧3例;男性38例,女性22例;年龄最小7岁,最大72岁,20~40岁占多数。均为鼻中隔前下部粘膜反复出血,经其他方法治疗无效.治疗方法 病人取坐位或半卧位,术者与患者相对而坐.1%地卡因麻黄素棉片贴附在鼻中隔粘膜出血区.并压迫止血.数分钟更换一次,至出血停止取下棉片,把浸有生理盐水纱布的铅板垫贴于腮部。选择好适
Since May 1988, our hospital has adopted the YD-5 light-weight thermocoagulation apparatus manufactured by Suzhou Medical Device Factory to treat diathermy on the surface of the nasal septum and the lower part of the recurrent nasal bleeding. The report is as follows. Clinical data observed in 60 cases, of which 26 cases of right, 31 cases of left and 3 cases of bilateral; 38 cases of males and 22 females; the youngest 7 years old, maximum 72 years old, 20 to 40 years majority. Are mucosal bleeding in the lower part of the nasal septum, repeated by the other methods of treatment ineffective treatment of patients sitting or semi-recumbent position, the patient sitting with the patient relative .1% digocaine ephedrine cotton attached to the nasal septum mucosa bleeding. And oppression to stop bleeding.A few minutes to replace, to stop bleeding to stop the cotton piece, soaked in saline gauze pad attached to the cheek plate. Choose a good fit