运用正交设计方法对SPME-GC法测试三氯乙烯、四氯乙烯的固相微萃取条件进行优化。首先选择样品量、NaCl用量、萃取温度、萃取时间、解析温度等因素,设计5因素3水平正交试验方案。分析数据得到优化条件为NaCl用量30 g/L,萃取温度25℃,解析温度210℃,同时得出样品量与萃取时间是对试验结果具有显著意义的影响因素,采用二次回归正交组合设计试验对其进一步优化,并对结果进行回归分析,得到最优条件为样品量为5.5 mL,萃取时间为20.13 min。
The orthogonal design method was used to optimize the SPME-GC method for the determination of trichlorethylene and tetrachlorethylene. First select the sample size, NaCl dosage, extraction temperature, extraction time, temperature and other factors, the design of 5 factors and 3 levels of orthogonal test program. The optimum conditions for the analysis were that the amount of NaCl was 30 g / L, the extraction temperature was 25 ℃ and the temperature was 210 ℃. The sample size and extraction time were significant influencing factors for the test results. The quadratic regression orthogonal design The test was further optimized, and the results were analyzed by regression analysis, the optimal conditions for the sample volume of 5.5 mL, extraction time was 20.13 min.